Bharat Rays logoBharat Rays
Get a quote

Buyer guide · imaging

DR vs CR vs film

Three ways to make the image


Every X-ray machine makes the same thing, an exposure. What turns it into an image is the receptor: a film, a CR imaging plate or a DR flat panel. Here is how they differ, in plain words.

Film
Darkroom and chemicals
CR
Plates read in a reader
DR
Panel, image on the console

Side by side

What each method needs in your room.

FilmCRComputed radiographyDRDirect digital radiography
ReceptorFilm in a cassetteImaging plate in a cassetteFlat panel detector
After the exposureDevelop in a darkroom with chemicalsCarry the cassette to a CR reader to scanImage goes to the console by cable or Wi-Fi
ImageOn film onlyDigitalDigital
Copies for patientsThe film itselfPrint over DICOMPrint over DICOM
Extra equipmentDarkroom, processor, chemicalsCR reader and platesPanel and acquisition PC
A summary of how each method works. Ask us which fits your room and workload.

How Bharat Rays fits in

Capture: the BR-1717S DR panel

A 17 × 17 inch IGZO flat panel detector, wireless and wired in one box, with CsI or GOS scintillator, 3072 × 3072 pixels at 140 µm and automatic exposure detection. Full specifications.

Print: DIPROX and DICOM Print Pro

Your CR or DR console prints to a Windows PC as if it were a film imager; the software prints on medical inkjet film from 8 × 10 inch to A3. How it works.

Questions buyers ask

Short, plain answers. Anything else: call 1800 309 9729, toll free.

What is the difference between CR and DR?

In CR (computed radiography) the exposure is stored on an imaging plate in a cassette, which is then carried to a reader that scans it into a digital image. In DR (direct digital radiography) a flat panel detector turns the X-rays into a digital image itself and sends it straight to the console, with no plate to carry or scan.

Can I add DR to my existing X-ray machine?

A DR panel that triggers from the beam, with automatic exposure detection, needs no cable to the generator, so it can work with an existing machine. The Bharat Rays BR-1717S supports automatic exposure detection and a line trigger, and is cassette-sized (ISO 4090), so it fits a bucky like a cassette.

How do I give patients a film with CR or DR?

Digital consoles send images over DICOM. DICOM print software, such as DIPROX, receives the film from the console and prints it on a Windows printer on medical film, from 8 × 10 inch to A3.

Get a quote

Toll free
1800 309 9729
Phone
+91 88102 21120
WhatsApp
Message +91 84487 41120
Email
info@waymedhealth.com
Address
B-47, Sector 6, Noida, Uttar Pradesh 201301

Goes straight to our sales team. We use these details only to reply to you. Privacy.