X-ray machines · line frequency
100 mA X-ray machine
FIX · CBM · SBM
The line-frequency 100 mA, built three ways: on a fixed tube stand (FIX), on a counter-balanced mobile base (CBM), or on a spring-balanced mobile base with an actuator arm (SBM). The FIX is rated 25 to 100 mA with an 8 kW output and runs on 230 V AC.


- Rating
- 25 to 100 mA
- Output
- 8 kW
- Timer
- 0.06 to 5 s
- Supply
- 230 V AC
100 mA FIX specification
Copied from the printed BHARAT RAYS 100 mA FIX sheet.
| 100 mA FIXLine frequency | |
|---|---|
| Radiography rating | 25 to 100 mA |
| Output | 8 kW |
| Rectification | Full-wave rectified |
| Timer | 0.06 to 5 s |
| Display | Digital display |
| X-ray tube | XD-3 or imported |
| Power supply | 230 V AC |
| Protection | Electronic overload protection |
| Tube stand | Fixed |

Three builds
One generator, three ways to hold the tube.


100 mA CBM
Counter-balanced mobile
- Stand
- Counter-balanced tube column with the control cabinet, on a wheeled base

100 mA SBM
Spring-balanced mobile
- Stand
- Spring-balanced arm worked by an actuator, on a wheeled base
Questions buyers ask
Short, plain answers. Anything else: call 1800 309 9729, toll free.
What is a 100 mA X-ray machine?
An X-ray machine whose generator can drive up to 100 milliamperes (mA) of tube current. It is the usual first fixed or mobile machine for general radiography. The Bharat Rays 100 mA FIX is rated 25 to 100 mA with an 8 kW output, a full-wave rectified line-frequency generator, an exposure timer from 0.06 to 5 seconds and a 230 V AC supply.
FIX, CBM or SBM: which build should I choose?
FIX has a fixed tube stand, for a dedicated X-ray room. CBM and SBM stand on wheeled bases, so the machine can move between rooms. On the CBM the tube is counter-balanced on its column; on the SBM it rides on a spring-balanced arm worked by an actuator.
What do mA, mAs, kVp and kW mean?
mA is the X-ray tube current. mAs is that current multiplied by the exposure time in seconds, which sets how much radiation one exposure makes. kVp is the peak tube voltage, which sets how penetrating the beam is. kW is the power of the generator: the more power, the shorter the exposure needed for the same mAs.
Do you need an AERB licence to use an X-ray machine in India?
Yes. The Atomic Energy Regulatory Board (AERB) requires every user of medical diagnostic X-ray equipment to hold a licence for operation, applied for through its e-LORA portal. The equipment must be type-approved and bought from an authorised supplier, and the room must follow AERB's layout and shielding guidelines. See AERB's e-LORA guidelines for diagnostic radiology, and ask us about the model you are buying.