Bharat Rays logoBharat Rays
Get a quote

X-ray machines · line frequency

100 mA X-ray machine

FIX · CBM · SBM


The line-frequency 100 mA, built three ways: on a fixed tube stand (FIX), on a counter-balanced mobile base (CBM), or on a spring-balanced mobile base with an actuator arm (SBM). The FIX is rated 25 to 100 mA with an 8 kW output and runs on 230 V AC.

Bharat Rays 100 mA CBM: counter-balanced tube column with a control cabinet on a wheeled base.Bharat Rays 100 mA SBM: spring-balanced arm worked by an actuator, on a wheeled base.
Move over the machine to see it in X-ray
Rating
25 to 100 mA
Output
8 kW
Timer
0.06 to 5 s
Supply
230 V AC

100 mA FIX specification

Copied from the printed BHARAT RAYS 100 mA FIX sheet.

100 mA FIXLine frequency
Radiography rating25 to 100 mA
Output8 kW
RectificationFull-wave rectified
Timer0.06 to 5 s
DisplayDigital display
X-ray tubeXD-3 or imported
Power supply230 V AC
ProtectionElectronic overload protection
Tube standFixed
Download the 100 mA FIX specification sheet (PDF, 1.0 MB). Ask for the CBM and SBM sheets with your quote.
The BHARAT RAYS-100 control panel: kV, mA and seconds readouts, three dials and two meters.
The 100 mA control panel, marked BHARAT RAYS-100.

Three builds

One generator, three ways to hold the tube.

The 100 mA control panel.

100 mA FIX

Fixed tube stand

Stand
Fixed
Rating
25 to 100 mA, 8 kW
Power
230 V AC

Get a quote

Bharat Rays 100 mA CBM on its wheeled base.

100 mA CBM

Counter-balanced mobile

Stand
Counter-balanced tube column with the control cabinet, on a wheeled base

Get a quote

Bharat Rays 100 mA SBM with its actuator arm.

100 mA SBM

Spring-balanced mobile

Stand
Spring-balanced arm worked by an actuator, on a wheeled base

Get a quote

Questions buyers ask

Short, plain answers. Anything else: call 1800 309 9729, toll free.

What is a 100 mA X-ray machine?

An X-ray machine whose generator can drive up to 100 milliamperes (mA) of tube current. It is the usual first fixed or mobile machine for general radiography. The Bharat Rays 100 mA FIX is rated 25 to 100 mA with an 8 kW output, a full-wave rectified line-frequency generator, an exposure timer from 0.06 to 5 seconds and a 230 V AC supply.

FIX, CBM or SBM: which build should I choose?

FIX has a fixed tube stand, for a dedicated X-ray room. CBM and SBM stand on wheeled bases, so the machine can move between rooms. On the CBM the tube is counter-balanced on its column; on the SBM it rides on a spring-balanced arm worked by an actuator.

What do mA, mAs, kVp and kW mean?

mA is the X-ray tube current. mAs is that current multiplied by the exposure time in seconds, which sets how much radiation one exposure makes. kVp is the peak tube voltage, which sets how penetrating the beam is. kW is the power of the generator: the more power, the shorter the exposure needed for the same mAs.

Do you need an AERB licence to use an X-ray machine in India?

Yes. The Atomic Energy Regulatory Board (AERB) requires every user of medical diagnostic X-ray equipment to hold a licence for operation, applied for through its e-LORA portal. The equipment must be type-approved and bought from an authorised supplier, and the room must follow AERB's layout and shielding guidelines. See AERB's e-LORA guidelines for diagnostic radiology, and ask us about the model you are buying.

Get a quote

Toll free
1800 309 9729
Phone
+91 88102 21120
WhatsApp
Message +91 84487 41120
Email
info@waymedhealth.com
Address
B-47, Sector 6, Noida, Uttar Pradesh 201301

Goes straight to our sales team. We use these details only to reply to you. Privacy.