Buyer guide · equipment
How to choose an X-ray machine
Seven questions to answer first
The right X-ray machine depends less on the biggest number and more on where your patients are, how many you see, and the power and room you have. Answer these seven questions and the choice usually makes itself.
- Range
- 2 mA to 40 kW
- 230 V
- 100 mA FIX, 15 kW
- 440 V
- 300 mA, 40 kW
The seven questions
Where will the X-ray be taken?
At the bedside, in wards and ICUs, at home or at camps, the machine has to go to the patient: a portable or handheld unit or a 5 or 8 kW high-frequency mobile. In a dedicated X-ray room, a fixed set with a table and a bucky does more.
How many patients a day, and which examinations?
Thin parts such as hands, feet and limbs need little output; chest, spine and abdomen need more, and a busy department needs a machine that keeps up all day. A smaller room often starts with a 100 mA set; a busy department looks at 300 or 500 mA or a 15 to 40 kW high-frequency room.
What power supply do you have?
Check before you choose. From the printed Bharat Rays sheets: the 100 mA FIX and the 15 kW high-frequency run on 230 V AC (the 15 kW on single phase); the 300 mA needs 440 V; the 40 kW needs 440 V three phase.
Line frequency or high frequency?
A line-frequency generator works at the mains frequency, so its tube voltage ripples with every cycle. A high-frequency generator converts the mains to a much higher frequency first, which gives a nearly steady voltage and more consistent exposures from a smaller transformer. Both are in the range; compare them.
How will you make the image?
Film needs a darkroom and chemicals; CR reads imaging plates in a reader; DR captures the image on a flat panel at the bucky. A DR panel can be added to a new or existing machine, and DICOM print software prints films for patients. See DR vs CR vs film.
Is the room ready?
The room must follow AERB's layout and shielding rules, and the machine needs an AERB licence before use. See X-ray room requirements in India, and plan for aprons, a barrier and other protection.
Who will service it?
Ask about the warranty on your purchase and what happens after it. An AMC or CMC keeps the machine covered.
The Bharat Rays range at a glance
Where each family usually fits. Ask us to match one to your room.
| FitsTypical setting | Generator | Power (from the sheets) | |
|---|---|---|---|
| Portable 2 / 5 / 10 mA | Bedside, home visits, camps, thin body parts | HF (2, 5 mA), LF (10 mA) | Ask for the sheet |
| 100 mA FIX / CBM / SBM | A smaller X-ray room, or a mobile set between rooms | Line frequency | 230 V AC (FIX) |
| 300 / 500 mA | A busy X-ray department | Line frequency | 440 V (300 mA) |
| 5 / 8 kW mobile | Wards and ICUs | High frequency | Ask for the sheet |
| 15 / 32 / 40 kW room | A full department room | High frequency | 230 V single phase (15 kW), 440 V three phase (40 kW) |