Bharat Rays logoBharat Rays
Get a quote

Radiation protection

Radiation protection

Lead wear · barriers · 0.25 and 0.5 mm Pb


X-rays scatter off the patient, and the staff beside the table catch some of it every exposure. Bharat Rays makes the lead they wear, in two weights, and the barriers, screens and curtains they stand behind.

Teal Bharat Rays apron with skirt, Bharat Rays mark on the pocket.
Move over the machine to see it in X-ray
Lead
0.25 or 0.5 mm Pb
Pieces
15
Protects
Staff, patients, room

See the lead

Inside the circle you see what an X-ray beam sees: the lead prints white because it stops the beam; skin and cloth print dark.

A technician in the full Bharat Rays protective kit: lead cap, thyroid guard, apron with skirt, arm guards, gloves and foot covers.
Move over him to see what the beam sees

The kit, by body zone

Fifteen pieces of protection: what the technician wears, head to foot, and what stands between the room and the beam.

Teal Bharat Rays lead cap.
Lead capHead
Royal blue lead cap, 0.5 mm Pb.
Lead cap, 0.5 mm PbHead
Teal thyroid guard wrapped around the neck.
Thyroid guardNeck
Navy lead apron.
Lead apronTorso
Teal apron with skirt.
Apron with skirtTorso
Teal lead-free apron.
Lead-free apronTorso
Teal arm guards over both forearms.
Arm guardsArms
Green lead gloves.
Lead gloves, greenHands
Blue lead gloves.
Lead gloves, blueHands
Teal gonad shield on a waist belt.
Gonad shieldPelvis
Short teal lead skirt.
Lead skirtPelvis
Knee-length full cover skirt.
Full cover skirtPelvis
Teal foot protection covers, knee to ankle.
Foot protection coverLegs

Two weights of lead

Lead equivalence is the thickness of plain lead a garment matches.

0.25 mm Pb
Lighter to wear through a long shift. AERB's minimum for protective aprons.
0.5 mm Pb
More lead between you and the scatter.

For the room

Barriers and screens on castors, and a lead curtain.

A triple panel protection barrier: three hinged panels on castors, with a viewing window in the centre panel.

Triple panel barrier

On castors · viewing window

Build
Three hinged panels on castors
Window
In the centre panel

Get a quote

A mobile protection screen on castors, with a viewing window.

Mobile screen

On castors · viewing window

Build
Single screen on castors
Window
Viewing window

Get a quote

A teal lead curtain panel printed with the Bharat Rays mark.

Lead curtain

Printed with the mark

Finish
Teal, printed with the Bharat Rays mark

Get a quote

Questions buyers ask

Short, plain answers. Anything else: call 1800 309 9729, toll free.

What radiation protection does an X-ray room need?

AERB's safety code for medical diagnostic X-ray equipment and installations (AERB/RF-MED/SC-3, Rev. 2) sets the requirements. Among them: lead-lined doors (1.7 mm lead equivalent), a protective barrier at the control console (1.5 mm lead equivalent), and protective aprons of at least 0.25 mm lead equivalence. The room layout must follow AERB's layout and shielding guidelines. Read the current code and the shielding guidelines before you build: these are AERB's requirements, and AERB's documents are the authority.

0.25 or 0.5 mm Pb: which apron weight?

Lead equivalence is the thickness of plain lead a garment matches. 0.25 mm Pb is lighter to wear through a long shift and is the minimum AERB sets for protective aprons; 0.5 mm Pb puts more lead between you and the scatter. Ask which pieces come in which weight when you request a quote.

Who needs radiation protection during an X-ray?

Anyone who stays in the room during an exposure: the operator, staff who hold or position a patient, and family members helping. X-rays scatter off the patient, so lead aprons, thyroid guards and a protective barrier for the operator are part of every installation. See Bharat Rays radiation protection.

Get a quote

Toll free
1800 309 9729
Phone
+91 88102 21120
WhatsApp
Message +91 84487 41120
Email
info@waymedhealth.com
Address
B-47, Sector 6, Noida, Uttar Pradesh 201301

Goes straight to our sales team. We use these details only to reply to you. Privacy.