X-ray machines · high frequency
High-frequency X-ray machines
5 · 8 kW mobile · 15 · 32 · 40 kW room
High-frequency generators with microcontroller consoles, in two forms: a mobile column on a wheeled base at 5 or 8 kW, and floor-column room systems with a radiography table at 15, 32 or 40 kW. The 15 and 40 kW cover 40 to 125 kVp and 1 to 200 mAs.


- Outputs
- 5 to 40 kW
- kV
- 40 to 125 kVp
- mAs
- 1 to 200
- Up to
- 500 mA
Two forms
A mobile you wheel to the patient, or a room system you build a department around.


15 · 32 · 40 kW
Room system
- Format
- Floor column, table and console
- Range
- 40 to 125 kVp, up to 500 mA (40 kW)
- Tube stand
- Counter-balanced, floor and ceiling-free

The console
Feather-touch · microcontroller
- Display
- kVp and mAs, digital
- Hand switch
- Dual action, retractable cord
15 kW and 40 kW specifications
Copied from the printed Bharat Rays sheets.
| 15 kWHigh frequency | 40 kWHigh frequency | |
|---|---|---|
| Output power | 15 kW | 40 kW |
| kV range | 40 to 125 kVp | 40 to 125 kVp |
| Radiography mA | 250 mA | 500 mA |
| mAs range | 1 to 200 mAs | 1 to 200 mAs |
| Control panel | Feather-touch, microcontroller based; digital display of kVp and mAs | Feather-touch, microcontroller based; digital display of kVp and mAs |
| Interlocks | Earth fault, voltage error, kVp error, filament error, thermal protection | Earth fault, voltage error, kVp error, filament error, thermal protection |
| Hand switch | Dual action, retractable cord | Dual action, retractable cord |
| X-ray tube | Rotating anode, monoblock tube head | Rotating anode, monoblock tube head |
| Collimator | Manually operated | Manually operated |
| Tube stand | Fully counter-balanced, floor and ceiling-free | Fully counter-balanced, floor and ceiling-free |
| Power supply | 230 V AC, single phase, ±10% | 440 V AC, three phase, ±10% |
Questions buyers ask
Short, plain answers. Anything else: call 1800 309 9729, toll free.
What is the difference between line-frequency (LF) and high-frequency (HF) X-ray machines?
A line-frequency generator works its high-voltage transformer at the mains frequency (50 Hz in India) and rectifies the output, so the tube voltage rises and falls with each mains cycle. A high-frequency generator first converts the mains into a much higher frequency, which gives a nearly steady tube voltage from a smaller transformer and more consistent exposures. In the Bharat Rays range the 10 mA portable and the 100, 300 and 500 mA sets are line frequency; the 2 mA handheld, the 5 mA portable and the 5 to 40 kW machines are high frequency.
Mobile or room system?
The 5 and 8 kW mobile stands on a wheeled base and moves to the patient, in wards and ICUs. The 15, 32 and 40 kW room systems are installed with a floor column and a radiography table for a full X-ray department. Check the supply: the 15 kW runs on 230 V AC single phase, the 40 kW on 440 V AC three phase.
What do mA, mAs, kVp and kW mean?
mA is the X-ray tube current. mAs is that current multiplied by the exposure time in seconds, which sets how much radiation one exposure makes. kVp is the peak tube voltage, which sets how penetrating the beam is. kW is the power of the generator: the more power, the shorter the exposure needed for the same mAs.
Do you need an AERB licence to use an X-ray machine in India?
Yes. The Atomic Energy Regulatory Board (AERB) requires every user of medical diagnostic X-ray equipment to hold a licence for operation, applied for through its e-LORA portal. The equipment must be type-approved and bought from an authorised supplier, and the room must follow AERB's layout and shielding guidelines. See AERB's e-LORA guidelines for diagnostic radiology, and ask us about the model you are buying.
Get a quote
- Toll free
- 1800 309 9729
- Phone
- +91 88102 21120
- Message +91 84487 41120
- info@waymedhealth.com
- Address
- B-47, Sector 6, Noida, Uttar Pradesh 201301
Request sent
Reference
Thank you, . Our team will call you back on .
Anything urgent? Call 1800 309 9729, toll free.