X-ray machines · high frequency

High-frequency X-ray machines

5 · 8 kW mobile · 15 · 32 · 40 kW room


High-frequency generators with microcontroller consoles, in two forms: a mobile column on a wheeled base at 5 or 8 kW, and floor-column room systems with a radiography table at 15, 32 or 40 kW. The 15 and 40 kW cover 40 to 125 kVp and 1 to 200 mAs.

Bharat Rays 5/8 kW HF mobile X-ray: a column with the tube on an arm and a digital control panel, on a wheeled base.Bharat Rays high-frequency room system: floor column with the tube, a radiography table and a digital console.
Move over the machine to see it in X-ray
Outputs
5 to 40 kW
kV
40 to 125 kVp
mAs
1 to 200
Up to
500 mA

Two forms

A mobile you wheel to the patient, or a room system you build a department around.

Bharat Rays 5/8 kW HF mobile X-ray on a wheeled base.

5 · 8 kW

Mobile column

Format
Mobile column
Generator
High frequency
Controls
Digital console

Get a quote

Bharat Rays high-frequency room system with floor column and table.

15 · 32 · 40 kW

Room system

Format
Floor column, table and console
Range
40 to 125 kVp, up to 500 mA (40 kW)
Tube stand
Counter-balanced, floor and ceiling-free

Get a quote

The high-frequency console: a blue membrane keypad with a digital display and a hand switch.

The console

Feather-touch · microcontroller

Display
kVp and mAs, digital
Hand switch
Dual action, retractable cord

15 kW and 40 kW specifications

Copied from the printed Bharat Rays sheets.

15 kWHigh frequency40 kWHigh frequency
Output power15 kW40 kW
kV range40 to 125 kVp40 to 125 kVp
Radiography mA250 mA500 mA
mAs range1 to 200 mAs1 to 200 mAs
Control panelFeather-touch, microcontroller based; digital display of kVp and mAsFeather-touch, microcontroller based; digital display of kVp and mAs
InterlocksEarth fault, voltage error, kVp error, filament error, thermal protectionEarth fault, voltage error, kVp error, filament error, thermal protection
Hand switchDual action, retractable cordDual action, retractable cord
X-ray tubeRotating anode, monoblock tube headRotating anode, monoblock tube head
CollimatorManually operatedManually operated
Tube standFully counter-balanced, floor and ceiling-freeFully counter-balanced, floor and ceiling-free
Power supply230 V AC, single phase, ±10%440 V AC, three phase, ±10%
From the printed Bharat Rays 15 kW and 40 kW specification sheets: 15 kW sheet (PDF, 1.1 MB) · 40 kW sheet (PDF, 1.1 MB). The 32 kW and the 5 and 8 kW mobiles have no printed sheet on this site: ask for theirs with your quote.

Questions buyers ask

Short, plain answers. Anything else: call 1800 309 9729, toll free.

What is the difference between line-frequency (LF) and high-frequency (HF) X-ray machines?

A line-frequency generator works its high-voltage transformer at the mains frequency (50 Hz in India) and rectifies the output, so the tube voltage rises and falls with each mains cycle. A high-frequency generator first converts the mains into a much higher frequency, which gives a nearly steady tube voltage from a smaller transformer and more consistent exposures. In the Bharat Rays range the 10 mA portable and the 100, 300 and 500 mA sets are line frequency; the 2 mA handheld, the 5 mA portable and the 5 to 40 kW machines are high frequency.

Mobile or room system?

The 5 and 8 kW mobile stands on a wheeled base and moves to the patient, in wards and ICUs. The 15, 32 and 40 kW room systems are installed with a floor column and a radiography table for a full X-ray department. Check the supply: the 15 kW runs on 230 V AC single phase, the 40 kW on 440 V AC three phase.

What do mA, mAs, kVp and kW mean?

mA is the X-ray tube current. mAs is that current multiplied by the exposure time in seconds, which sets how much radiation one exposure makes. kVp is the peak tube voltage, which sets how penetrating the beam is. kW is the power of the generator: the more power, the shorter the exposure needed for the same mAs.

Do you need an AERB licence to use an X-ray machine in India?

Yes. The Atomic Energy Regulatory Board (AERB) requires every user of medical diagnostic X-ray equipment to hold a licence for operation, applied for through its e-LORA portal. The equipment must be type-approved and bought from an authorised supplier, and the room must follow AERB's layout and shielding guidelines. See AERB's e-LORA guidelines for diagnostic radiology, and ask us about the model you are buying.